{"id":2323,"date":"2016-01-19T10:40:33","date_gmt":"2016-01-19T09:40:33","guid":{"rendered":"http:\/\/anpsthemes.com\/construction\/?page_id=1296"},"modified":"2016-11-25T15:07:12","modified_gmt":"2016-11-25T14:07:12","slug":"registracija-in-obdelava-podatkov","status":"publish","type":"page","link":"https:\/\/www.l-plan.si\/en\/products\/registracija-in-obdelava-podatkov\/","title":{"rendered":"Upgrading the test unit \u02ddLegaline data acquisition\u02dd"},"content":{"rendered":"[vc_row][vc_column][vc_column_text]\n<p style=\"text-align: center;\"><strong>Upgrade your test unit with <\/strong><\/p>\n<p style=\"text-align: center;\"><strong>Legaline data acquisition &amp; processing system<\/strong><\/p>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;2506&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]\n<p>Test screens and reports[\/vc_column_text][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1453450201221{margin-bottom: 15px !important;}&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;2503&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; onclick=&#8221;custom_link&#8221;][vc_column_text]Raiway brakes testing[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;2504&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; onclick=&#8221;custom_link&#8221;][vc_column_text]Leakage detection[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;2505&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; onclick=&#8221;custom_link&#8221;][vc_column_text]Valves testing[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]\n<ol>\n<li><strong>Direct integration<\/strong><\/li>\n<\/ol>\n<p>Legaline Valve Test Data Acquisition System and pressure sensors can be mounted \u2013 Integrated into the existing test bench.<\/p>\n<p>Integration should be done in the Customer workshop.<\/p>\n<ol start=\"2\">\n<li><strong>Integration by Industrial Cabinet System<\/strong><\/li>\n<\/ol>\n<p>The Legaline System is build into the Industrial Cabinet and connected to stabile Test Unit by high pressure flexible pipes:<\/p>\n<ul>\n<li>Air \/ water side high pressure installation with pressure sensors &amp; overload protection.<\/li>\n<li>The LEGALINE electronic digital data acquisition device.<\/li>\n<li>Sensors: pressure sensors, lift laser sensor, sound sensor\u2026<\/li>\n<li>Connectors for lift and sound measuring, outlet coupling for calibrating the sensor and system.<\/li>\n<li>PC, LCD, color printer\u2026<\/li>\n<li>Software Valve Test with Database.<\/li>\n<li>Connection to BUBBLE TEST device.<\/li>\n<li>Other on request.<\/li>\n<\/ul>\n<p>Benefit:System is completely autonomous, so intervention into Customer existing Test unit is not required!<\/p>\n<ol start=\"3\">\n<li><strong>Integration by Industrial Case system<\/strong><\/li>\n<\/ol>\n<p>The Legaline System is build into the Industrial Case and connected to stabile Test Unit by high pressure flexible pipes. Benmefit: The System could be use in workshop or in the field.<\/p>\n<p>Legaline Valve test Data Acquisition system includes also two IMPORTANT BENEFITS:<\/p>\n<ol>\n<li>Proportional Auto Control of Clamping Force<\/li>\n<li>Automatic Testing procedure<\/li>\n<li>Bubble couter Sytem \u2013 seat leak detection<\/li>\n<\/ol>\n<p>Emphasis on High Accuracy? By Legaline Device Environment Influences Validation!<\/p>\n<p>Standard Temperature range \u00a00\u00b0 C to + 40\u00b0 C<\/p>\n<p>The Legaline CSPRS is designed\u00a0 according to EN ISO\/IEC 17025, EN ISO\/IEC 17020).<\/p>\n<ul>\n<li>Automatic calculation of measurement uncertainty.<\/li>\n<li>Correction or compensation of environment influences.<\/li>\n<li>System automatically calculated resultants acceptance criteria from Valves Standards.<\/li>\n<li>Trend (history) function.<\/li>\n<\/ul>\n<p><strong>Testing \/ Inspection \/ Calibration methods used by L-plan devices and the L-plan as Conformity\u00a0 Assessment \u2013 Inspection Body are approved by several Institutes and Conformity assessment bodies:<\/strong><\/p>\n<ul>\n<li><strong>T\u00dcV Nord Germany<\/strong><\/li>\n<li><strong>Bureau Veritas<\/strong><\/li>\n<li><strong>Slovenian Acreditation institute <\/strong><\/li>\n<li><strong>DET Norske Veritas<\/strong><\/li>\n<li><strong>Slovenian Metrology Institute<\/strong><\/li>\n<li><strong>Slovenian Quality Institute<\/strong><\/li>\n<\/ul>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row content_placement=&#8221;middle&#8221; css=&#8221;.vc_custom_1480082528364{padding-bottom: 30px !important;background-color: #ffffff !important;}&#8221; el_class=&#8221;background-image-left&#8221;][vc_column][vc_custom_heading text=&#8221;Recent products&#8221; font_container=&#8221;tag:h2|text_align:left|color:%23000000&#8243; use_theme_fonts=&#8221;yes&#8221; el_class=&#8221;title&#8221; css=&#8221;.vc_custom_1480082669315{margin-bottom: 60px !important;}&#8221;][vc_row_inner][vc_column_inner width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;2960&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; onclick=&#8221;custom_link&#8221; link=&#8221;https:\/\/www.l-plan.si\/en\/products\/atum-c\/&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;2959&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; onclick=&#8221;custom_link&#8221; link=&#8221;https:\/\/www.l-plan.si\/en\/products\/atum-h\/&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;2951&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; onclick=&#8221;custom_link&#8221; link=&#8221;https:\/\/www.l-plan.si\/en\/products\/zaviralnik\/&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;2964&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; onclick=&#8221;custom_link&#8221; link=&#8221;https:\/\/www.l-plan.si\/en\/products\/legaline-valve-test\/&#8221;][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1479979967761{background-color: #3c3c3c !important;}&#8221;][vc_column][vc_custom_heading text=&#8221;Recent projects &#038; News&#8221; font_container=&#8221;tag:h2|text_align:left|color:%23ffffff&#8221; use_theme_fonts=&#8221;yes&#8221; el_class=&#8221;title&#8221; css=&#8221;.vc_custom_1480073477841{margin-bottom: 60px !important;}&#8221;][vc_basic_grid post_type=&#8221;post&#8221; max_items=&#8221;3&#8243; item=&#8221;3808&#8243; grid_id=&#8221;vc_gid:1480082507927-3267682b-b358-1&#8243;][\/vc_column][\/vc_row]\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text] Upgrade your test unit with Legaline data acquisition &amp; processing system [\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;2506&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text] Test screens and reports[\/vc_column_text][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1453450201221{margin-bottom: 15px !important;}&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;2503&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; onclick=&#8221;custom_link&#8221;][vc_column_text]Raiway brakes testing[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;2504&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; onclick=&#8221;custom_link&#8221;][vc_column_text]Leakage detection[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;2505&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; &hellip;<\/p>\n","protected":false},"author":7,"featured_media":0,"parent":2659,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.l-plan.si\/en\/wp-json\/wp\/v2\/pages\/2323"}],"collection":[{"href":"https:\/\/www.l-plan.si\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.l-plan.si\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.l-plan.si\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.l-plan.si\/en\/wp-json\/wp\/v2\/comments?post=2323"}],"version-history":[{"count":8,"href":"https:\/\/www.l-plan.si\/en\/wp-json\/wp\/v2\/pages\/2323\/revisions"}],"predecessor-version":[{"id":3998,"href":"https:\/\/www.l-plan.si\/en\/wp-json\/wp\/v2\/pages\/2323\/revisions\/3998"}],"up":[{"embeddable":true,"href":"https:\/\/www.l-plan.si\/en\/wp-json\/wp\/v2\/pages\/2659"}],"wp:attachment":[{"href":"https:\/\/www.l-plan.si\/en\/wp-json\/wp\/v2\/media?parent=2323"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}