{"id":2661,"date":"2016-09-07T10:36:23","date_gmt":"2016-09-07T09:36:23","guid":{"rendered":"http:\/\/www.l-plan.si\/?page_id=2661"},"modified":"2016-11-25T15:09:27","modified_gmt":"2016-11-25T14:09:27","slug":"atum-h","status":"publish","type":"page","link":"https:\/\/www.l-plan.si\/en\/products\/atum-h\/","title":{"rendered":"Valve testing in production \u02ddLL ATUM-H\u02dd"},"content":{"rendered":"[vc_row][vc_column][vc_column_text]\n<h4 style=\"text-align: center;\"><strong> Testing of valves in the production process with the Legaline Atum-H device<\/strong><\/h4>\n<p style=\"text-align: center;\"><iframe loading=\"lazy\" data-cookieconsent=\"statistics, marketing\" data-src=\"https:\/\/www.youtube.com\/embed\/5Umzf0bYHdo\" width=\"854\" height=\"480\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><div class=\"cookieconsent-optout-statistics cookieconsent-optout-marketing\"><\/div><\/p>\n<p style=\"text-align: center;\">.<\/p>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;2999&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]Testing device Atum-H is designed for testing the characteristics of valves in the production process of Herz manufacturer:<\/p>\n<ul>\n<li>Ball valves for technical gases according to DIN 3230 T5 PG3 in the valve production process<\/li>\n<li>Testing the flow characteristics of ball valves, pressure regulators, and other valves, developed in Herz.<\/li>\n<\/ul>\n<p>The testing unit Legaline ATUM-H provides the following tests and consists of:<\/p>\n<ul>\n<li>Automatic valve clamping unit, which clamps valves DN 8 up to DN 50 or more (with internal or external thread).<\/li>\n<li>The system for measuring water flow from 0.5 m3\/h to 50m3\/h, with the accuracy of +\/- 3% FS, under pressure of 10 bar and temperatures up to 120 \u00b0 C.<\/li>\n<li>Two pressure sensors of 10 bar, a temperature of 120 \u00b0 C, accuracy of +\/- 0,25% FS, for measuring a pressure difference.<\/li>\n<li>Temperature sensors up to 120 \u00b0 C.<\/li>\n<li>Connection part\u00a0 in A\/D unit for the rotary sensor &#8211; encoder<\/li>\n<li>Connection part\u00a0 in A\/D unit for the force sensor<\/li>\n<li>Connection part\u00a0 in A\/D unit for the displacement sensor for valve spindle lift measuring<\/li>\n<li>Water heater for heating water in the system (in 2 hours from 20 \u00b0 C to 120 \u00b0 C).<\/li>\n<li>Water tank 300 l, PN 10.<\/li>\n<li>Pumps system for hot water, p=10 bar, t=120\u00b0C, Q=0.5 m3\/h do 50m3\/h<\/li>\n<li>Controls for continuously increasing \/ reducing pumps flow<\/li>\n<li>Cards to convert the analog signal from the electronic unit, for the supervision of the operation of test unit ATUM \u2013 H, including the operation speed control of the pump rotation.<\/li>\n<\/ul>\n<p>Scoop and processing of data is implemented by:<\/p>\n<ul>\n<li>The central electronic unit Legaline Atum-H for connection of all sensors and actuators, sensors and other measurers, electromagnetic valves&#8230; in combination with Legaline ATUM-H software.<\/li>\n<li>Software Legaline ATUM-H, which:\n<ul>\n<li>Processes the sensor data<\/li>\n<li>Displays the results in the form of diagrams,<\/li>\n<li>Enable salso the possibility of data export of measurement results into Excel table.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>The software records the measurements in continuous and parametric mode. It allows you to create a variety of protocols for measuring and storage in the database.<\/p>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row content_placement=&#8221;middle&#8221; css=&#8221;.vc_custom_1480082528364{padding-bottom: 30px !important;background-color: #ffffff !important;}&#8221; el_class=&#8221;background-image-left&#8221;][vc_column][vc_custom_heading text=&#8221;Recent products&#8221; font_container=&#8221;tag:h2|text_align:left|color:%23000000&#8243; use_theme_fonts=&#8221;yes&#8221; el_class=&#8221;title&#8221; css=&#8221;.vc_custom_1480082669315{margin-bottom: 60px !important;}&#8221;][vc_row_inner][vc_column_inner width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;2960&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; onclick=&#8221;custom_link&#8221; link=&#8221;https:\/\/www.l-plan.si\/en\/products\/atum-c\/&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;2959&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; onclick=&#8221;custom_link&#8221; link=&#8221;https:\/\/www.l-plan.si\/en\/products\/atum-h\/&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;2951&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; onclick=&#8221;custom_link&#8221; link=&#8221;https:\/\/www.l-plan.si\/en\/products\/zaviralnik\/&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;2964&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; onclick=&#8221;custom_link&#8221; link=&#8221;https:\/\/www.l-plan.si\/en\/products\/legaline-valve-test\/&#8221;][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1479979967761{background-color: #3c3c3c !important;}&#8221;][vc_column][vc_custom_heading text=&#8221;Recent projects &#038; News&#8221; font_container=&#8221;tag:h2|text_align:left|color:%23ffffff&#8221; use_theme_fonts=&#8221;yes&#8221; el_class=&#8221;title&#8221; css=&#8221;.vc_custom_1480073477841{margin-bottom: 60px !important;}&#8221;][vc_basic_grid post_type=&#8221;post&#8221; max_items=&#8221;3&#8243; item=&#8221;3808&#8243; grid_id=&#8221;vc_gid:1480082507927-3267682b-b358-1&#8243;][\/vc_column][\/vc_row]\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text] Testing of valves in the production process with the Legaline Atum-H device . [\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;2999&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]Testing device Atum-H is designed for testing the characteristics of valves in the production process of Herz manufacturer: Ball valves for technical gases &hellip;<\/p>\n","protected":false},"author":7,"featured_media":0,"parent":2659,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.l-plan.si\/en\/wp-json\/wp\/v2\/pages\/2661"}],"collection":[{"href":"https:\/\/www.l-plan.si\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.l-plan.si\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.l-plan.si\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.l-plan.si\/en\/wp-json\/wp\/v2\/comments?post=2661"}],"version-history":[{"count":15,"href":"https:\/\/www.l-plan.si\/en\/wp-json\/wp\/v2\/pages\/2661\/revisions"}],"predecessor-version":[{"id":4004,"href":"https:\/\/www.l-plan.si\/en\/wp-json\/wp\/v2\/pages\/2661\/revisions\/4004"}],"up":[{"embeddable":true,"href":"https:\/\/www.l-plan.si\/en\/wp-json\/wp\/v2\/pages\/2659"}],"wp:attachment":[{"href":"https:\/\/www.l-plan.si\/en\/wp-json\/wp\/v2\/media?parent=2661"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}