{"id":4438,"date":"2017-07-03T14:11:45","date_gmt":"2017-07-03T13:11:45","guid":{"rendered":"http:\/\/www.l-plan.si\/es\/?page_id=4438"},"modified":"2017-07-03T14:11:45","modified_gmt":"2017-07-03T13:11:45","slug":"calibracion-e-inspeccion-de-manometros","status":"publish","type":"page","link":"https:\/\/www.l-plan.si\/es\/productos\/calibracion-e-inspeccion-de-manometros\/","title":{"rendered":"CALIBRACI\u00d3N E INSPECCI\u00d3N DE MAN\u00d3METROS"},"content":{"rendered":"[vc_row][vc_column][vc_column_text]\n<p style=\"text-align: center;\"><strong>Calibraci\u00f3n \/ Inspecci\u00f3n de los man\u00f3metros y sensores en el terreno<\/strong><\/p>\n<p style=\"text-align: center;\">Mediante el dispositivo Legaline Manotest de la empresa L-PLAN<\/p>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_gallery type=\u00bbnivo\u00bb interval=\u00bb3&#8243; images=\u00bb3121,3122&#8243; img_size=\u00bbfull\u00bb][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]\n<h3>\u00bfC\u00f3mo funciona el Sistema Legaline Manotest?<\/h3>\n<p>El Sistema permite calibrar man\u00f3metros de tubo Bourdon, sensores de presi\u00f3n anal\u00f3gicos y digitales. El Sistema Legaline Manotest puede aplicarse f\u00e1cilmente a otros tipos de equipos de medici\u00f3n como sensores de temperatura, sensores PT, etc.<\/p>\n<p>El software se divide en tres m\u00f3dulos, cada uno especificando de acuerdo con las solicitudes est\u00e1ndar adecuadas.<\/p>\n<p>Como referencia se utilizan sensores de presi\u00f3n digitales de alta precisi\u00f3n y con compensaci\u00f3n de temperatura.<\/p>\n<p style=\"text-align: justify;\">La incertidumbre de medici\u00f3n calculada autom\u00e1ticamente depende principalmente de la elecci\u00f3n de la referencia apropiada.<\/p>\n<h3>Rango de calibraci\u00f3n<\/h3>\n<p>El rango de calibraci\u00f3n depende de la precisi\u00f3n de la referencia. La precisi\u00f3n de los sensores de presi\u00f3n digitales usados comienza en 0.05% FS.<\/p>\n<p>El rango de presi\u00f3n no est\u00e1 limitado por el software o por el Sistema Legaline. De acuerdo con la demanda del cliente, elegimos el generador de presi\u00f3n adecuado.<\/p>\n<h3>Inspection \/ Calibration Report<\/h3>\n<p>Los informes de calibraci\u00f3n \/ inspecci\u00f3n est\u00e1n dise\u00f1ados de acuerdo con los requisitos de EN ISO \/ IEC 17025 \/ 17020, EN ISO 1070 y OIML R 23. Otras normas pueden ser f\u00e1cilmente implementadas en las solicitudes.<\/p>\n<p>El informe contiene los datos generales y t\u00e9cnicos pertinentes, los resultados y el gr\u00e1fico de los valores de presi\u00f3n, obtenidos durante el procedimiento de calibraci\u00f3n, respectivamente el diagrama de errores, por lo cual la recalibraci\u00f3n puede ser m\u00e1s f\u00e1cil.<\/p>\n<p style=\"text-align: justify;\">Mediante el Sistema Legaline Manotest la incertidumbre de la medici\u00f3n causada por el factor humano se reduce al m\u00ednimo igual que la automatizaci\u00f3n de las secuencias de calibraci\u00f3n.<\/p>\n<h3>Todo el Sistema se construye de acuerdo con:<\/h3>\n<ul>\n<li>EURMAET \/ cg-17 \/ v.01, julio de 2007<\/li>\n<li>EA-10\/17 Directrices de EA sobre la calibraci\u00f3n de man\u00f3metros electromec\u00e1nicos, julio de 2002<\/li>\n<li>DKD-R 6-1, Calibraci\u00f3n de los man\u00f3metros, 01\/2003<\/li>\n<li>ISO \/ IEC 17025: 2005 \u2013 Requisitos generales para la competencia de los laboratorios de comprobaci\u00f3n y calibraci\u00f3n<\/li>\n<li>Man\u00f3metros \u2013 Parte 1: Man\u00f3metros de tubo Bourdon \u2013 Dimensiones, metrolog\u00eda, requisitos y comprobaci\u00f3nes<\/li>\n<li>Man\u00f3metros \u2013 Parte 3: Man\u00f3metros de membrana y c\u00e1psula \u2013 Dimensiones, metrolog\u00eda, requisitos y comprobaci\u00f3nes<\/li>\n<li>OIML R 23, Edici\u00f3n 1975, Man\u00f3metros de neum\u00e1ticos para veh\u00edculos de motor<\/li>\n<\/ul>\n<h3>El m\u00e9todo de calibraci\u00f3n del dispositivo Legaline Manotest y la empresa L-PLAN como un Organismo de Inspecci\u00f3n y Evaluaci\u00f3n de Conformidad, son aprobados por:<\/h3>\n<ul>\n<li>Bureau Veritas<\/li>\n<li>Instituto de Acreditaci\u00f3n de Eslovenia (basado en ILAC MRA \u2013 International Laboratory Accreditation Cooperation \u2013 Cooperaci\u00f3n Internacional de Acreditaci\u00f3n de Laboratorios)<\/li>\n<li>Instituto Esloveno de Metrolog\u00eda<\/li>\n<\/ul>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row content_placement=\u00bbmiddle\u00bb css=\u00bb.vc_custom_1480077817206{padding-bottom: 30px !important;background-color: #ffffff !important;}\u00bb el_class=\u00bbbackground-image-left\u00bb][vc_column][vc_custom_heading text=\u00bbProductos recientes\u00bb use_theme_fonts=\u00bbyes\u00bb el_class=\u00bbtitle\u00bb css=\u00bb.vc_custom_1499087454330{margin-bottom: 60px !important;}\u00bb][vc_row_inner][vc_column_inner width=\u00bb1\/4&#8243;][vc_single_image image=\u00bb2960&#8243; img_size=\u00bbfull\u00bb alignment=\u00bbcenter\u00bb onclick=\u00bbcustom_link\u00bb link=\u00bbhttps:\/\/www.l-plan.si\/produkti\/atum-c\/\u00bb][\/vc_column_inner][vc_column_inner width=\u00bb1\/4&#8243;][vc_single_image image=\u00bb2951&#8243; img_size=\u00bbfull\u00bb alignment=\u00bbcenter\u00bb onclick=\u00bbcustom_link\u00bb link=\u00bbhttps:\/\/www.l-plan.si\/produkti\/zaviralnik\/\u00bb][\/vc_column_inner][vc_column_inner width=\u00bb1\/4&#8243;][vc_single_image image=\u00bb2959&#8243; img_size=\u00bbfull\u00bb alignment=\u00bbcenter\u00bb onclick=\u00bbcustom_link\u00bb link=\u00bbhttps:\/\/www.l-plan.si\/produkti\/atum-h\/\u00bb][\/vc_column_inner][vc_column_inner width=\u00bb1\/4&#8243;][vc_single_image image=\u00bb2964&#8243; img_size=\u00bbfull\u00bb alignment=\u00bbcenter\u00bb onclick=\u00bbcustom_link\u00bb link=\u00bbhttps:\/\/www.l-plan.si\/produkti\/mobilni-test-ventilov\/\u00bb][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row css=\u00bb.vc_custom_1479979978909{background-color: #3c3c3c !important;}\u00bb][vc_column][vc_custom_heading text=\u00bbProyectos recientes y noticias\u00bb font_container=\u00bbtag:h2|text_align:left|color:%23ffffff\u00bb use_theme_fonts=\u00bbyes\u00bb el_class=\u00bbtitle\u00bb css=\u00bb.vc_custom_1499087459859{margin-bottom: 60px !important;}\u00bb][vc_basic_grid post_type=\u00bbpost\u00bb max_items=\u00bb3&#8243; item=\u00bb3808&#8243; grid_id=\u00bbvc_gid:1499087127153-ad58fa78-4a01-8&#8243;][\/vc_column][\/vc_row]\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text] Calibraci\u00f3n \/ Inspecci\u00f3n de los man\u00f3metros y sensores en el terreno Mediante el dispositivo Legaline Manotest de la empresa L-PLAN [\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_gallery type=\u00bbnivo\u00bb interval=\u00bb3&#8243; images=\u00bb3121,3122&#8243; img_size=\u00bbfull\u00bb][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text] \u00bfC\u00f3mo funciona el Sistema Legaline Manotest? El Sistema permite calibrar man\u00f3metros de tubo Bourdon, &hellip;<\/p>\n","protected":false},"author":7,"featured_media":0,"parent":4415,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.l-plan.si\/es\/wp-json\/wp\/v2\/pages\/4438"}],"collection":[{"href":"https:\/\/www.l-plan.si\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.l-plan.si\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.l-plan.si\/es\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.l-plan.si\/es\/wp-json\/wp\/v2\/comments?post=4438"}],"version-history":[{"count":1,"href":"https:\/\/www.l-plan.si\/es\/wp-json\/wp\/v2\/pages\/4438\/revisions"}],"predecessor-version":[{"id":4439,"href":"https:\/\/www.l-plan.si\/es\/wp-json\/wp\/v2\/pages\/4438\/revisions\/4439"}],"up":[{"embeddable":true,"href":"https:\/\/www.l-plan.si\/es\/wp-json\/wp\/v2\/pages\/4415"}],"wp:attachment":[{"href":"https:\/\/www.l-plan.si\/es\/wp-json\/wp\/v2\/media?parent=4438"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}